Portable Power Station Calculator: Runtime & Battery Size

Estimate portable power station runtime from battery watt-hours and device watts, or find the capacity for your target runtime.

Manufacturer reference · your actual draw may differ.

Try an example

Estimated runtime

18.5 h

1,152 Wh × 0.85 ÷ 53 W

Constant-load estimate. Check inverter output and startup demand.

Calculation assumptions
Planning estimate · 0.85 usable-energy factorReference library: 2026-08-09Product manuals
Calculation method & limitations

Calculation method

EstimateFormulaExample
RuntimeBattery Wh × 0.85 ÷ load W1,152 Wh × 0.85 ÷ 104 W ≈ 9.4 h
Battery sizeLoad W × hours ÷ 0.85, rounded up53 W × 8 h ÷ 0.85 ≈ 499 Wh

Usable capacity factor 0.85 (composite: ~90% inverter efficiency folded in); device draw treated as constant. Runtime values are estimates — always confirm with your device’s official label. Not medical advice.

No separate reserve, battery aging, temperature correction or inverter idle-load model is included. Startup compatibility, outlet voltage, approved adapters and shutdown behavior need a separate check. For medical equipment, agree on a backup plan with your equipment provider.

Appliance power references

Appliance power references

Recorded 2026-08-09. Manufacturer references and illustrative presets are identified separately. Use measured consumption for your own setup.

ApplianceDrawReference
CPAP — no heated humidifier (ResMed AirSense 11)Manufacturer reference30 WResMed official typical power consumption (AirSense 11, no humidifier)
CPAP — heated humidifier on (ResMed AirSense 11)Manufacturer reference53 WResMed official typical power consumption (AirSense 11, heated humidifier on)
12V compressor fridge (Dometic CFX3 55, rated)Manufacturer reference104 WDometic CFX3 55 official spec (rated input current DC 8.7 A)

Official rated DC input current 8.7 A at 12 V (12 V × 8.7 A ≈ 104 W); rated AC input power 50 W.

12V compressor fridge (Dometic CFX3 55, average draw)Manufacturer reference13 WDometic CFX3 55 official spec (energy consumption 1.1 Ah/h @ 12V DC)

Official energy consumption 1.1 Ah/h at 12 V DC ≈ 13 W average (ambient 90 °F / internal 39 °F); compressor fridges cycle.

RV rooftop air conditioner (13.5K BTU class, running)Manufacturer reference1500 WDometic 13.5K BTU rooftop AC official spec (FreshJet 5 Series 15K product page)

Dometic 13.5K BTU rooftop AC class: ~13 A @ 115 V ≈ 1,500 W steady; startup surge ≈ 3,000 W (built-in hard start on current FreshJet 5 Series 15K reduces it).

Water pump (RV, 12V)Illustrative preset100 WDometic MagDrive P030M 12V pump official page (typical RV pump class — illustrative)

Typical 12V RV pump label draw (illustrative — no single official figure across models).

WiFi router + modemIllustrative preset15 WTypical label value (illustrative)

Typical label value (illustrative — manufacturers rarely publish draw).

LED lighting (set)Illustrative preset50 WTypical label value (illustrative)

Typical label value for an RV/off-grid LED set (illustrative).

LED camping lightIllustrative preset10 WTypical label value (illustrative)

Typical label value (illustrative).

LaptopIllustrative preset65 WTypical label value (illustrative)

Typical draw while charging (illustrative; Apple official adapters range 35–96 W).

Home refrigerator (compressor)Illustrative preset150 WTypical label value (illustrative)

Typical label draw (illustrative — varies by model per EnergyGuide).

Sump pump (1/3 HP)Illustrative preset800 WTypical label value (illustrative)

Typical 1/3 HP label draw (illustrative); startup ≈ 1,200 W — changes inverter sizing.

Starlink Mini (DC direct / off-grid)Manufacturer reference25 WStarlink Mini official specification (average power 25–40 W)

Official average power draw 25–40 W at 12–48V DC input (typical ~25 W average in active roaming, no snow melt).

Starlink Standard (Gen 3, AC)Manufacturer reference60 WStarlink Standard Gen 3 official specification (average power 50–75 W)

Official average power draw 50–75 W via included AC power supply.

Electric heated blanket (camping, low)Illustrative preset50 WTypical camping electric blanket draw (illustrative)

Typical low/medium setting draw for portable 12V / 110V camping blanket (illustrative — cycles 30–60 W).

Coffee maker (drip / pod single-serve)Illustrative preset900 WTypical drip coffee maker label draw (illustrative)

Typical drip / pod brewer heating element draw (illustrative); requires station inverter rated >= 1000 W.

Power station specifications & manuals

Power station references

Capacity and continuous AC ratings are recorded specifications. Startup ratings and regional differences must be checked in the exact manual.

ModelBatteryContinuous ACDocuments
Jackery Explorer 300Jackery Explorer 300293 Wh300 WPhoto & manualRecorded 2026-08-09
Jackery Explorer 1000 v2Jackery Explorer 1000 v21,070 Wh1,500 WPhoto & manualRecorded 2026-08-09
Bluetti AC180Bluetti AC1801,152 Wh1,800 WPhoto & manualRecorded 2026-08-09
EcoFlow DELTA 3EcoFlow DELTA 31,024 Wh1,800 WPhoto & manualRecorded 2026-08-09
Anker SOLIX C1000Anker SOLIX C10001,056 Wh1,800 WPhoto & manualRecorded 2026-08-09
Bluetti AC200LBluetti AC200L2,048 Wh2,400 WPhoto & manualRecorded 2026-08-09
Common questions

How is power station runtime calculated?

Nominal battery Wh × 0.85 ÷ constant device watts. The 0.85 combined usable-energy factor is a planning assumption, not a measured efficiency for every station. No separate backup reserve is included.

What battery capacity do I need for eight hours?

Multiply device watts by target hours and divide by 0.85. A constant 53 W load for eight hours needs 499 Wh nominal capacity before a separate reserve. This energy calculation does not establish inverter or medical-device compatibility.

Does this check appliance startup surge?

The runtime mode flags a continuous load above a selected station’s recorded continuous AC rating. It does not verify startup surge, surge duration, voltage or automatic shutdown behavior. Check the exact manuals separately.

Why can actual runtime differ?

Battery age, temperature, inverter idle consumption and changing device draw affect runtime. Measure cycling loads over a representative period and confirm essential equipment backup requirements with its provider.

Reference notes & updates

Specification source notes

Fridge rated input and average energy use are different presets. The 104 W rated-input example is not a constant draw measured across an entire refrigerator cycle.

Data history

2026-08-09: recorded CPAP, refrigerator and RV air-conditioner references. Generic equipment presets remain illustrative. 2026-11-01: simplified the interface and corrected mode-specific exports; source dates remain unchanged.